Abstract

Effects of inlet subcooling on pool boiling heat transfer in a vertical annulus with closed bottom have been studied experimentally. For the test, a tube of 19.1 mm diameter and the water at atmospheric pressure have been used. Up to 50 K of pool subcooling has been tested and results of the annulus are compared with the data of a single unrestricted tube. The increase in pool subcooling results in much change in heat transfer coefficients. As the heat flux increases and the subcooling decreases, a deterioration of heat transfer coefficients is observed. The governing mechanisms are suggested as single-phase heat transfer and liquid agitation for the single tube while liquid agitation and bubble coalescence are the major factors at the bottom closed annulus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.