Abstract
Objective: For patients of TOF with pulmonary annular hypoplasia, reconstruction of right ventricular outflow tract (RVOT) often requires a trans annular patch (TAP). The present study aims to compare the outcomes of TOF repair using Polytetrafluoroethylene (PTFE) patch versus autologous glutaraldehyde fixed pericardial patch for RVOT reconstruction. Materials and methods: 103 consecutive patients undergoing TOF repair in whom TAP was required were randomized into two groups: Group I (pericardial patch), Group II (PTFE patch). Postoperative outcomes in terms of postoperative heart rhythm, duration of mechanical ventilation, mediastinal and pleural drainage, length of stay in intensive care unit (ICU) and hospital mortality were assessed. A separate team of cardiologists independently evaluated pre- and post-operative gradients across the RVOT, degree of pulmonary insufficiency, right ventricular systolic function. Results: There were no significant differences between the two groups in terms of the incidence of postoperative arrhythmias, duration of mechanical ventilation, length of intensive care unit or hospital stay. The requirement of inotropes was no different in the PTFE patch group as compared with the pericardial patch group (16.84 ± 7.04 vs. 17.90 ± 6.71, median 19 vs. 20, p = 0.825). The re-exploration rate was higher in the PTFE group as compared with the pericardial patch group (6 vs. 1). Postoperative Echocar-diography revealed no differences in the RV systolic function between the two groups before discharge. Conclusion: In patients undergoing TOF repair, using a PTFE patch yields comparable results. However, the efficacy of PTFE will only be established once; mid-term and long-term results are available.
Highlights
Of all the cyanotic heart conditions, Tetralogy of Fallot (TOF) is the most common which is found in 3.5% of all infants born diagnosed with a congenital heart defect [1]
The present study aims to compare the outcomes of TOF repair using Polytetrafluoroethylene (PTFE) patch versus autologous glutaraldehyde fixed pericardial patch for right ventricular outflow tract (RVOT) reconstruction
Materials and methods: 103 consecutive patients undergoing TOF repair in whom trans annular patch (TAP) was required were randomized into two groups: Group I, Group II (PTFE patch)
Summary
Of all the cyanotic heart conditions, Tetralogy of Fallot (TOF) is the most common which is found in 3.5% of all infants born diagnosed with a congenital heart defect [1]. An increasingly greater number of patients with TOF survive well into adulthood
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.