Abstract

Central MessageRV-PA conduits using PTFE leaflets inside a tube of thicker PTFE show great promise as a more durable alternative to xenograft and allograft conduits.See Article page 2567. RV-PA conduits using PTFE leaflets inside a tube of thicker PTFE show great promise as a more durable alternative to xenograft and allograft conduits. See Article page 2567. Miyazaki and Yamagishi1Miyazaki T. Yamagishi M. Maeda Y. Taniguchi S. Fujita S. Hongu H. et al.Long-term outcomes of expanded polytetrafluoroethylene conduits with bulging sinuses and a fan-shaped valve in right ventricular outflow tract reconstruction..J Thorac Cardiovasc Surg. 2018; 155: 2567-2576Abstract Full Text Full Text PDF Scopus (45) Google Scholar are to be commended for their excellent polytetrafluoroethylene (PTFE) valved right ventricle–pulmonary artery (RV-PA) conduit clinical results, which are illustrated in this article. Allografts and bovine jugular vein conduits have been the most popular RV-PA conduits in the United States and Europe for the last 2 decades. These conduits function well for a few years, and their durability has improved. However, their limited long-term durability necessitates multiple conduit exchanges over the patient's lifetime. Allografts generally are not available in Japan, and the bovine jugular vein conduit has become available only in the last 2 to 3 years. Japan's need for a right ventricular outflow tract reconstruction material stimulated their early interest in PTFE as a pulmonary valve substitute. Yamagishi first demonstrated the use of 0.1-mm PTFE material, designed and developed for pericardial closure for making a synthetic pulmonary valve leaflet, and published its use as a monocusp valve in 1993.2Yamagishi M. Kurosawa H. Outflow reconstruction of tetralogy of fallot using a gore-tex valve.Annals of Thorac Surg. 1993; 56 (discussion 1416-7): 1414-1416Abstract Full Text PDF PubMed Scopus (51) Google Scholar We adopted and modified the monocusp technique 24 years ago and continue to use it for pulmonary valve reconstruction in patients requiring a transannular patch. Soon after their monocusp experience, Miyazaki and Yamagishi1Miyazaki T. Yamagishi M. Maeda Y. Taniguchi S. Fujita S. Hongu H. et al.Long-term outcomes of expanded polytetrafluoroethylene conduits with bulging sinuses and a fan-shaped valve in right ventricular outflow tract reconstruction..J Thorac Cardiovasc Surg. 2018; 155: 2567-2576Abstract Full Text Full Text PDF Scopus (45) Google Scholar began making handmade conduits using 0.1-mm PTFE for leaflets and a thicker tubular PTFE for the conduit. They recently added sinuses and fan-shaped leaflets since 2010 based on hydrodynamic experiments in a pulse duplicator. This article summarizes the outcomes of 902 patients with handmade PTFE valved conduits constructed by a single surgeon. The conduits included bulging sinuses and fan-shaped PTFE leaflets in 9 different sizes (8-24 mm in diameter) and were implanted in children and adults at 65 Japanese hospitals between 2001 and 2015. The mean patient age was 3.9 years, and mean weight was 12.5 kg. The patients had a variety of congenital cardiac malformations requiring right ventricular outflow tract reconstruction. The patients' hospital survival was excellent at 98%, and late survival was 95.5% to 15 years. They compared patients by age greater or less than 2 years of age. Those aged less than 2 years (n = 292) had a freedom from conduit replacement of 90% and 74% at 5 and 10 years, respectively. Freedom from conduit replacement in the group aged more than 2 years was greater than 95% at 10 years. Their conduits showed excellent freedom from infection, stenosis, and regurgitation (>95%) during follow-up (median, 4.8 years). Fifty-five conduits (6%) were replaced mostly for outgrowth or stenosis proximal or distal to the valved conduit. Fifty-three patients required balloon catheter intervention for proximal or distal stenosis. This large Japanese multicenter experience with a handmade conduit may not be immediately transferable to the United States and Europe because the Food and Drug Administration and other governing bodies are not likely to approve handmade valved conduits because of inconsistent quality control. The authors' experience is an excellent proof of concept and will open the door for industry to provide a consistent product for congenital heart surgeons. PTFE valved conduits as shown in this article show real promise as an alternative to currently available RV-PA conduits. Longer follow-up will be necessary to see if these conduits continue to perform as well as the authors report. Long-term outcomes of expanded polytetrafluoroethylene conduits with bulging sinuses and a fan-shaped valve in right ventricular outflow tract reconstructionThe Journal of Thoracic and Cardiovascular SurgeryVol. 155Issue 6PreviewVarious types of conduits are available for right ventricular outflow tract (RVOT) reconstruction. We have developed an expanded polytetrafluoroethylene (ePTFE) conduit with bulging sinuses and a fan-shaped ePTFE valve. This study summarized the results of a multicenter study evaluating the valved ePTFE conduit. Full-Text PDF Open Archive

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call