Abstract

A system of beam emission spectroscopy (BES) for density fluctuation measurements having the sightlines passing through the plasma in the poloidal direction was developed in the Large Helical Device (LHD). Even though the angle between the beam and the sightline is slightly larger than a right angle, Doppler-shifted beam emission can be distinguished from background emission because of the high energy (120-170 keV) of the neutral beam for heating with negative ion sources. Spatial resolution is about 0.1-0.2 in the normalized radius. Compared with the prototype BES system with toroidal sightlines, the BES system with poloidal sightlines showed improved spatial resolution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.