Abstract

According to a survey to all Swedish delivery departments, nitrous-oxide-oxygen analgesia given on demand is frequently used by women in labour. Excess gas scavenging equipment was lacking in 12 out of a total of 73 delivery wards in September 1982. The effects of various room ventilation and excess gas scavenging methods on the nitrous oxide concentration in the delivery room were investigated. The 8 h time weighted average (TWA) for midwives was 24 ppm nitrous oxide with room ventilation in accordance with the Swedish recommended standard and with excess gas scavenging using 1.61 reservoir tube volume. For women in labour, close scavenging using various modifications of conventional tube systems was shown to be practically impossible to apply. Close scavenging via a specially designed plastic hood surrounding the face of the woman in labour resulted in very low nitrous oxide concentrations in the delivery room, even when the room ventilation was reduced to very low values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.