Abstract

The polarographic behaviour of the widely used anti-inflammatory agent, oxyphenbutazone, was studied. It is determined polarographically by conversion to the nitroso derivative characterized by a cathodic, irreversible, diffusion-controlled wave. The method is applied to the determination of 2.5-10 mg/100 mL of oxyphenbutazone, with an accuracy of 99.9 +/- 1.38%. By differential pulse polarographic analysis, as little as 10 ppm oxyphenbutazone can be determined with an accuracy of 99.70 +/- 0.99% in pure powder and in some pharmaceutical formulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.