Abstract

False elevations of plasma lactate dehydrogenase (LDH), potassium and aspartate aminotransferase (AST) have been described, in relation to haemolysis, occurring most often by mechanical release during phlebotomy or specimen processing. We present the cases of two leukaemic patients with severe hyperleukocytosis for whom LDH, potassium and AST were dramatically but falsely elevated. This false elevation was not caused by haemolysis but could be related to white cells lysis during transport through a pneumatic transportation system, enhanced by a specific fragility of leukaemic cells. Interestingly, this interference almost completely disappeared when serum rather than plasma was used, or when leukocytosis came back to normal. This work is meant to alert clinicians to the risks of errors in LDH, potassium and AST in leukaemic patients and suggest what precautions to take.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.