Abstract

AbstractProperly fabricated triangular‐plate added damping and stiffness (TADAS) devices can sustain a large number of yield reversals without strength degradation, thereby dissipating a significant amount of earthquake‐induced energy. A pronounced isotropic‐hardening effect is recognized in the force‐deformation relationships of the TADAS devices made from two grades of low yield strength steel. The proposed plasticity‐fibre model employing two surfaces (a yield surface and a bounding surface) in plasticity theory accurately predicts the experimental responses of the TADAS devices. This model is also implemented into a computer program DRAIN2D+ to investigate a frame response with the TADAS devices. Substructure pseudo‐dynamic tests and analytical studies of a two‐storey steel frame constructed with the low yield strength steel, LYP‐100 or LYP‐235 grade, TADAS devices confirm that the dynamic structural response can only be predicted if the proposed plasticity‐fibre model is used for LYP‐100 steel TADAS device. Copyright © 2002 John Wiley & Sons, Ltd.