Abstract

AbstractWe have utilized plasma immersion ion implantation (PIII) to demonstrate effective gettering of metallic impurities in silicon wafers. Metallic impurities such as Ni, Cu or Au were intentionally diffused into Si as marker impurities. The Ar or Ne atoms were ionized in an electron cyclotron resonance (ECR) plasma chamber. The ions were accelerated by a negative voltage applied to the wafer and implanted into the wafer. The as-implanted saturation dose can be as high as 5×1016cm−2. After an annealing step at 1000°C for 1 hour in a N2 ambient, the retained doses and the amount of gettered impurities were measured with Rutherford backscattering spectrometry (RBS). With a retained Ar dose in 1015cm−2 range after annealing, the gettered Ni, Cu and Au were 3.0×1014cm−2, 3.0×1014cm−2 and 4.4×1013cm−2 respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.