Abstract
The conventional method for determining the effective ion charge Zeff is based on measurements of the bremsstrahlung intensity in the spectral regions free from line radiation. This paper describes the design of the Zeff diagnostics at the Globus-M tokamak as well as the results of the first measurements. With allowance for the emission intensity estimates, the geometry of the experiment was chosen; the filter monochromators for recording bremsstrahlung were designed and manufactured. Using the Thomson scattering data on Te (R) and ne (R) profiles, time dependences Zeff (t) were obtained in several shots of the Globus-M tokamak. The results of simulations Zeff performed using the ASTRA transport code are consistent with these measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.