Abstract

Based on the pilot test, the feasibility of E lectrosorption Technology of industrial sewage treatment plant was studied. The result s show that, when the equipment w ater flow and electrode voltage appropriate, in the sewage plant industrial average conductivity row is 3277μS/cm, 4072μS/cm, averaged desalination rate is 74.8%, averaged water production rate is about 75.5%, average consu mption water of a ton is 2.46kW•H. E lectrosorption technology is g ood removal effect of salinity, chloride and total hardness , and water production rate is high, simple operation, can be used for desalination of industrial recyclin wastewater .

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call