Abstract
We studied the acoustic properties of liquid oxygen up to 90 T by means of ultrasound measurements. We observed a monotonic decrease of the sound velocity and an asymptotic increase of the sound attenuation when applying magnetic fields. The unusual attenuation, twenty times as large as the zero-field value, suggests strong fluctuations of the local molecular arrangement. We assume that the observed fluctuations are related to a liquid-liquid transition or crossover, from a small-magnetization to a large-magnetization liquid, which is characterized by a local-structure rearrangement. To investigate higher-field properties of liquid oxygen, we performed single-turn-coil experiments up to 180 T by means of the acoustic, dilatometric, magnetic, and optical techniques. We observed only monotonic changes of these properties, reflecting the absence of the proposed liquid-liquid transition in our experimental conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.