Abstract

We present a novel solution to accurately recover 3D dynamic flame temperature field based on physical parameters consistency. First, a new optical model is proposed to establish the relationship between the flame radiation and the radiance field, this model fully considers refractive effect caused by refraction index changing; Second, high dynamic range (HDR) cameras are used to take flame images, a lookup table is employed calculate temperature from radiance; Third, an algorithm is put forward to reconstruct the flame temperature field. Experimental results on real flame accord with physical facts, which demonstrate that our solution is validate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.