Abstract
We present a novel solution to accurately recover three-dimensional dynamic flame temperature field. Traditional flame temperature field reconstruction schemes take flame images with general industrial cameras and reconstruct flame temperature field under the assumption that the cameras can capture the full spectrum. However, the dynamic range of the general industrial camera is more restricted than that of the light from flame and camera response band is much narrower compared with the full spectrum. In this paper, we use high dynamic range to take flame images and reconstruct the flame radiant existence field on camera response band. Temperature field is calculated from radiant existence field via lookup table between them. Experimental results on real flame demonstrate that our approach is accurate and easy to implement. The rendering results of the flame-based temperature field accord with physical facts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.