Abstract

The application of radiotherapy to the treatment of cancer requires the knowledge of photon interaction coefficients such as mass attenuation (μm) and mass energy-absorption coefficients (μen/ρ). Although these coefficients have been determined for different tissues, it is lacking for the colorectal cancer (CRC) tissue in the literature. This study determines the μm and μen/ρ for the CRC tissue within the radiotherapy energy range. The CRC tissue from autopsy patients was freeze-dried, grounded into a fine powder, and made into pellets of 1 cm thickness. The elements detected in the CRC tissue using Rutherford backscattering spectrometry were used in XCOM to determine the theoretical values of μm and μen/ρ. The CRC tissue was again exposed to X-rays of energies of 6 and 15MV, respectively, to determine its experimental values of μm and μen/ρ. Elements detected included carbon, oxygen and nitrogen making up 96.67%, high atomic number and trace elements making up the remaining 3.33% fraction of the CRC tissue. The theoretical and experimental μm and μen/ρ values showed a good agreement of about 2% difference between them. These values can be used to simulate the CRC tissue with respect to μm and μen/ρ.