Abstract

Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multiple Coulomb scattering of the secondary electrons, are not accounted for by current photon dose calculation algorithms. As local interface effects are mainly due to the perturbation of secondary electrons, a photon-electron cascade model is proposed which incorporates explicit electron transport in the calculation of the primary photon dose component in heterogeneous media. The primary photon beam is treated as the source of many electron pencil beams. The latter are transported using the Fermi-Eyges theory. The scattered photon dose contribution is calculated with the dose spread array [T.R. Mackie, J.W. Scrimger, and J.J. Battista, Med. Phys. 12, 188-196 (1985)] approach. Comparisons of the calculation with Monte Carlo simulation and TLD measurements show good agreement for positions near the polystyrene-aluminum interfaces.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.