Abstract

A new, simplified solid phase extraction procedure for the determination of risperidone and 9-hydroxyrisperidone in human plasma has been developed. This method involves the use of an optimized extraction protocol developed in Waters OASIS® HLB 30mg 1cc extraction columns using 1 mL of human serum. Separation was performed by HPLC using a Waters XTerra RP-18 (5 µm, 150x4,6 mm) column with a mobile phase consisting in acetonitrile – potassium dihydrogen phosphate 50 mM pH 3.4 (27/73). UV detection at 278 nm was used to quantify analytes, encountering good linearity (r2 > 0.999) in the 2-100 ng/mL concentration range. The mean recovery was 92.4 % and 92.8 % for risperidone and 9-hydroxyrisperidone respectively, with an intraday – interday precision below 7%, and accuracy below 115 %. The method has been successfully applied in pharmacokinetic studies that require a large sample number.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.