Abstract
The preparation of the Safety Analysis Report for the 233-H Replacement Tritium Facility (RTF) requires permeation constants of hydrogen isotopes through butyl rubber, to estimate possible worker exposure given a certain level of tritium in the confinement gloveboxes. Literature values of the permeability constants for hydrogen isotopes and water vapor through butyl rubber at ambient temperature (22-25 C) have been converted to common units and are tabulated (Tables I and II). Permeation rates of tritiated species are the same as that of protium species, within experimental error. Thus, molecular protium and normal water vapor data serve to estimate tritium permeation rates. Because of vendor to vendor variability of permeability, especially of water vapor, vendor measurements of water vapor permeability should continue to be used to estimate permeation in SRS processes.