Abstract

The ionization beam profile monitor system for the Main Injector ring is under construction at Fermilab. The beam profile detector unit is installed inside the main magnet gap. The magnet has a novel configuration previously used for this type of application in the Main Injector. However, this magnet is far more compact with a higher quality field. Most flux from the main gap returns symmetrically along the beam pipe through two side gaps. It provides nearly full compensation to yield integrated magnetic field close to zero, and helps eliminate distortions of the circulating proton beam. The permanent magnet poles are assembled from SmCo5 bricks (0.5''×1''×2''), which have good thermal stability and reasonable cost. Further integrated field reduction is obtained by the use of a ferromagnetic plate that shunts the main gap. The plate position and flux shunting are adjusted in conjunction with magnetic measurements. Three permanent magnets were successfully fabricated and measured. Results of the magnet design, 3-D FEA analysis, and magnetic measurements by the rotational coil and the 3-D Hall probe will be presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.