Abstract
PM (Permanent Magnet) biased magnetic bearing with PM to replace the magnetic field produced by electromagnet an Active Magnetic Bearing generated static bias magnetic field, it can reduce the power consumption of power amplifier to reduce the number of turns of magnet safety, reduce the volume of magnetic bearings, reducing electromagnetic coil operating current, thereby reducing the power amplifier power control system and heat sink size, magnetic bearings significantly reduce power loss, and fundamentally reduce the cost of bearing. In this paper, a kind of PM biased magnetic bearings, describes its structure and working principle, derived a mathematical model of magnetic bearing and magnetic circuit of PM biased magnetic bearings are calculated, given the specific PM biased magnetic bearing size and accordingly calculate the parameters of magnetic bearings. A magnetic model constructed using Simulink simulation method, and constructed using this method, magnetic bearing specific mathematical model simulation results show that the rotor position in the balance, X and Y decoupling between the control winding, while the deviation from equilibrium position time, X and Y control coupling between the windings, the simulation results and the calculation results.