Abstract
ObjectiveRevascularization of the left subclavian artery (LSA) during zone 2 thoracic endovascular aortic repair (TEVAR) maintains collateral circulation to decrease ischemic complications, including stroke, spinal cord ischemia, and upper extremity ischemia. Both open surgical and endovascular LSA revascularization techniques have been described, each with unique risks and benefits. We describe our “periscope sandwich” technique for the LSA during zone 2 TEVAR, which maintains antegrade access to the distal abdominal aorta if subsequent interventions are necessary. Technical results and short-term outcomes are compared with LSA open surgical debranching. MethodsA single-institution retrospective review was performed for patients requiring zone 2 TEVAR with LSA revascularization by periscope sandwich technique or open surgical debranching with subclavian to carotid transposition (SCT) or carotid-subclavian bypass (CSB). The presenting aortic disease and perioperative details were recorded. Intraoperative angiography and postoperative computed tomography images were reviewed for occurrence of endoleak and branch patency. ResultsBetween January 2013 and December 2018, the LSA was revascularized by periscope sandwich in 18 patients, SCT in 22 patients, and CSB in 13 patients. Compared with open surgical debranching, periscope sandwich had a lower median estimated blood loss (100 mL vs 200 mL for pooled SCT and CSB; P = .03) and lower median case duration (133.5 minutes vs 226 minutes; P < .001). Contrast material volume (120 mL vs 120 mL; P = .98) and fluoroscopy time (13.1 minutes vs 13.3 minutes; P = .92) did not differ significantly between the groups. There was no difference in aorta-related mortality (P = .14), and LSA patency was 100%. Median follow-up for the periscope sandwich group was 11 months, with an overall estimated 91% freedom from gutter leak at 6 months. ConclusionsLSA periscope sandwich technique provides safe and effective LSA revascularization during zone 2 TEVAR. LSA periscope sandwich can be used emergently with off-the-shelf endovascular components and facilitates future branched-fenestrated endovascular repair of thoracoabdominal aortic diseases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.