Abstract
In this study, the performance test and defect anatomy analysis were carried out for a girth weld of the pipeline. The results of the girth weld tensile test, groove hammer break test and Vickers hardness test showed no obvious abnormality, and the impact toughness and bending test results were not ideal. In the conventional inspection process, it was found that there were tiny unfused girth welds at 6 o 'clock and 9 o 'clock positions, and the maximum direction size of defects on the wall thickness section was 1.57 mm. The defects at the position from 6 o 'clock to 7 o 'clock found by on-site X-ray detection were identified as the existing non-fusion defects by anatomical analysis, and should be considered as the root of incomplete welding defects that could not be completely eliminated during repair welding. The length and height of the defects are 9 mm and 1.38 mm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.