Abstract
ABSTRACT As building electrification is recognised as an important opportunity to reduce greenhouse gas emissions, the integration of solar energy and heat pump represents a promising solution towards net-zero carbon buildings. This paper presents a hybrid multifunctional solar-assisted heat pump (SAHP) system that can provide space heating, space cooling, domestic hot water, and onsite electricity generation. Photovoltaic-thermal collectors are used for electricity generation, heat collection, and radiative cooling. The system design and controls support fourteen operational modes involving different components. TRNSYS software is used to model and simulate the multifunctional SAHP system. With a 2-m3 storage tank and 30-m2 PVT collectors, the multifunctional SAHP system has a seasonal performance factor of 2.7 in Baltimore and 3.7 in Las Vegas. The onsite electricity generation can cover 53% of the building’s electricity needs in Baltimore and 83% in Las Vegas.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.