Abstract

<abstract> <p>Two handheld near infrared (NIR) spectrometers were used to quantify crude protein ($CP$) content of mixed forage and feedstuff composed of Sweet Bran, distiller's grains, corn silage, and corn stalk. First was a transportable spectrometer, which measured in the visible and NIR ranges (320–2500 nm) with a spectral interval of 1 nm (H1). Second was a smartphone spectrometer, which measured from 900–1700 nm with a spectral interval of 4 nm (H2). Spectral data of 147 forage and feed samples were collected by both handheld instruments and split into calibration ($n$ = 120) and validation ($n$ = 27) sets. For H1, only absorbances in the NIR region (780–2500 nm) were used in the multivariate analyses, while for H2, absorbances in the second and third overtone regions (940–1660 nm) were used. Principal component analysis (PCA) and partial least squares (PLS) regression models were developed using mean-centered data that had been preprocessed using standard normal variate (SNV) or Savitzky-Golay first derivative (SG1) or second derivative (SG2) algorithm. PCA models showed two major groups—one with Sweet Bran and distillers grains, and the other with corn silage and corn stalk. Using H1 spectra, the PLS regression model that best predicted $CP$ followed SG1 preprocessing. This model had low root mean square error of prediction ($RMSEP$ = 2.22%) and high ratio of prediction to deviation ($RPD$ = 5.24). With H2 spectra, the model best predicting $CP$ was based on SG2 preprocessing, returning $RMSEP$ = 2.05% and $RPD$ = 5.74. These values were not practically different than those of H1, indicating similar performance of the two devices despite having absorbance measurements only in the second and third overtone regions with H2. The result of this study showed that both handheld NIR instruments can accurately measure forage and feed $CP$ during screening, quality, and process control applications.</p> </abstract>

Highlights

  • In forages and feedstuffs, crude protein ( ) is one of the most regularly assessed constituents [1]

  • The result of this study showed that both handheld near infrared (NIR)

  • The scores plot of the Principal component analysis (PCA) of the raw spectra collected from H1 and H2 showed a similar pattern (Figure 1a,b) with corn stalk and corn silage samples close to each other, while Sweet

Read more

Summary

Introduction

In forages and feedstuffs, crude protein ( ) is one of the most regularly assessed constituents [1]. NIR technology is conducted with benchtop spectrometers that exhibit very high performance [5], giving low errors and accurate predictions of nutrient concentrations These instruments are too large and costly to be widely distributed and transported and are generally used in controlled environments. Advancements in optics and electronics have enabled the development of portable, handheld NIR spectrometers, which are relatively easy to operate and have reduced space and energy requirements [6] compared to benchtop spectrometers. These handheld units vary in cost, size, weight, type of power needed, robustness, user-friendliness, durability, accuracy of measurement, and performance reliability [7,8]. This study contributes to the ongoing process of validating the level of performance of miniaturized NIR instruments for utilization in the food and agriculture sector

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.