Abstract

In this study, the performance of a sludge thickening and reduction system coupled with filtration using a flat-sheet membrane was investigated. The effects of various factors such as HRT, flux and addition of coagulant were determined. TMP was observed to increase as the HRT decreases and the operating flux increases. The operating condition was then determined and the selected HRT and flux were 6.7days and 10.7L/m2h, respectively. Different operating HRT indicated the variation of hydraulic loading rates for the organics and other nutrients affecting membrane fouling, while varying the flux showed the rate of decrease of the membrane permeability. When coagulant was added, the rate of increase of TMP was decreased, allowing the system to be operated for a longer period of time. It was observed that inorganic coagulant was more effective than organic coagulant based on the final TMP. It also suggests that membrane fouling was better minimized with the addition of inorganic coagulant. It was found that the most essential factor on membrane fouling was the addition of coagulant, while the effect of HRT was observed to be the least influential among the other factors considered.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.