Abstract

Bioelectrochemical systems need an anode with a high abundance of exoelectrogenic bacteria for an optimal performance. Among all possible operational parameters for an efficient enrichment, the role of external resistance in microbial fuel cell (MFC) has gained a lot of interest since it indirectly poises an anode potential, a key parameter for biofilm distribution and morphology. Thus, this work aims at investigating and discussing whether bioanodes selected at different external resistances under MFC operation present different responses under both MFC and microbial electrolysis cell (MEC) operation. A better MEC performance (i.e. shorter start-up time, higher current intensity and higher H2 production rate) was obtained with an anode from an MFC developed under low external resistance. Quantitative real-time polymerase chain reaction (qPCR) confirmed that a low external resistance provides an MFC anodic biofilm with the highest content of Geobacter because it allows higher current intensity, which is correlated to exoelectrogenic activity. High external resistances such as 1,000 Ω led to a slower start-up time under MEC operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.