Abstract

Results from an experimental program on the behaviour of high strength concrete-filled steel hollow structural section (HSS) columns will be presented for three types of concrete filling. A comparison will be made of the fire-resistance performance of HSS columns filled with normal strength concrete, high strength concrete, and steel-fibre-reinforced high strength concrete. The various factors that influence the structural behaviour of high strength concrete-filled HSS columns under fire conditions are discussed. It is demonstrated that, in many cases, addition of steel fibres into high strength concrete improves the fire resistance and offers an economical solution for fire-safe construction.Key words: high strength concrete, steel columns, fire-resistance design, high-temperature behaviour, concrete-filled steel columns.