Abstract

To evaluate the image quality and utility of virtual monoenergetic images (VMI) of dual-layer spectrum computed tomography (DLSCT) in assessing preoperative T-stage for early rectal adenocarcinoma (ERA). This retrospective study included 67 ERA patients (mean age 62 ± 11.1 years) who underwent DLSCT and MR examination. VMI 40-200 keV and poly energetic image (PEI) were reconstructed. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and tumor contrast of different energy levels were calculated and compared, respectively. Two radiologists independently assess the image quality of the VMIs and PEI using 5-point scales. The diagnostic accuracies of DLSCT and HR-MRI for ERA T-staging were evaluated and compared. The maximum noise was observed at VMI 40 keV, and noise at VMI 40-200 keV in the arterial and venous phases showed no significant difference (all p > 0.05). The highest SNR and CNR were obtained at VMI 40 keV, significantly greater than other energy levels and PEI (all p < 0.05). Tumor contrast was more evident than PEI at 40-100 keV in the arterial phase and at 40 keV in the venous phase (all p < 0.05). When compared with PEI, VMI 40 keV yielded the highest scores for overall image quality, tumor visibility, and tumor margin delineation, especially in the venous phase (p < 0.05). The overall diagnostic accuracy of DLSCT and HR-MRI for T-stage was 65.67 and 71.64% and showed no significant difference (p > 0.05). VMI 40 keV improves image quality and accuracy in identifying lesions, providing better diagnostic information for ERA staging. Low-keV VMI from DLSCT can improve tumor staging accuracy for early rectal carcinoma, helping guide surgical intervention decisions, and has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC. • Compared with PEI, low-keV VIM derived from DLSCT, particularly at the 40 keV, significantly enhanced the objective and subjective image quality of ERA. • Using VMI 40 keV helped increase lesion detectability, leading to improved diagnostic accuracy for ERA. • Low-keV VMI from DLSCT has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.