Abstract
ObjectiveThis study aims to assess the diagnostic performance of Sonazoid-contrast-enhanced ultrasound (CEUS) in identifying definitive HCC within hepatic nodules in cirrhotic patients, comparing the KLCA-NCC 2022 and APASL 2017 diagnostic guidelines.Materials and methodsThis retrospective study analyzed cirrhotic patients who underwent Sonazoid-CEUS for liver lesion evaluation between October 2019 and October 2023. HCC diagnosis was based on the KLCA-NCC 2022 and APASL 2017 guidelines. Inter-reader agreement on CEUS imaging features and the diagnostic accuracy of the guidelines were evaluated. Sensitivity and specificity comparisons were made using McNemar’s test.ResultsAmong 400 patients with 432 lesions, CEUS showed excellent inter-reader consistency in detecting arterial phase hyperenhancement and Kupffer defects. The KLCA-NCC 2022 criteria notably enhanced sensitivity to 96.2%, with specificity and accuracy of 93.8% and 95.8%, respectively. APASL 2017 achieved the highest sensitivity at 97.8%, although specificity dropped to 46.9%, resulting in an accuracy of 90.3%. The KLCA-NCC 2022 guidelines demonstrated significantly higher specificity than APASL 2017 (p < 0.001), while APASL 2017 exhibited the highest sensitivity at 97.8%. Notably, the KLCA-NCC 2022 guidelines also demonstrated an impressive positive predictive value of 98.9%.ConclusionSonazoid-enhanced CEUS, particularly when applied using the KLCA-NCC 2022 guidelines, is an effective diagnostic tool for HCC.Critical relevance statementPerfluorobutane CEUS, particularly in accordance with the KLCA-NCC 2022 guidelines, emerges as a valuable adjunct for diagnosing HCC in cirrhotic patients. It demonstrates superior positive predictive value and specificity compared to APASL 2017, underscoring its potential as an effective diagnostic tool.Key PointsContrast-enhanced (CE)US using Sonazoid with KLCA-NCC 2022 guidelines is highly effective for HCC diagnosis.KLCA-NCC 2022 criteria showed high accuracy, 96.2% sensitivity, and 98.9% PPV.CEUS demonstrated excellent inter-reader consistency in detecting arterial phase hyperenhancement and Kupffer defects.Graphical
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.