Abstract
With ever-tightening emission regulations, particulate filters are critical for internal combustion engines to meet the stringent particulate matter emission standards. A fast way to predict the filter performance, instead of numerically solving the governing differential equations, is needed for filter design and selection, real-time control, malfunction detection, and deposit load sensing. Approximate analytical solutions for wall flow filters, considering asymmetric channels and arbitrary deposit amounts, are derived by a technique of successive approximation. The analytical predictions of filter pressure drop have been validated against both steady state and transient experimental measurements. Moreover, over a broad range of filter operating conditions, the accuracy of the second-order analytical solution is validated by comparisons with the numerical predictions. The derivation also provides analytical expressions for channel and wall velocity profiles along the filter length. This study reveals the...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.