Abstract
The accuracy and precision of an automated graph-cuts (GC) segmentation technique for dynamic contrast-enhanced (DCE) 3D MR renography (MRR) was analyzed using 18 simulated and 22 clinical datasets. For clinical data, the error was 7.2 +/- 6.1 cm(3) for the cortex and 6.5 +/- 4.6 cm(3) for the medulla. The precision of segmentation was 7.1 +/- 4.2 cm(3) for the cortex and 7.2 +/- 2.4 cm(3) for the medulla. Compartmental modeling of kidney function in 22 kidneys yielded a renal plasma flow (RPF) error of 7.5% +/- 4.5% and single-kidney GFR error of 13.5% +/- 8.8%. The precision was 9.7% +/- 6.4% for RPF and 14.8% +/- 11.9% for GFR. It took 21 min to segment one kidney using GC, compared to 2.5 hr for manual segmentation. The accuracy and precision in RPF and GFR appear acceptable for clinical use. With expedited image processing, DCE 3D MRR has the potential to expand our knowledge of renal function in individual kidneys and to help diagnose renal insufficiency in a safe and noninvasive manner.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.