Abstract

Testing for SARS-CoV-2 in resource-poor settings remains a considerable challenge. Gold standard nucleic acid tests are expensive and depend on availability of expensive equipment and highly trained laboratory staff. More affordable and easier rapid antigen tests are an attractive alternative. This study assessed field performance of such a test in western Kenya. We conducted a prospective multi-facility field evaluation study of NowCheck COVID-19 Ag-RDT compared to gold standard PCR. Two pairs of oropharyngeal and nasopharyngeal swabs were collected for comparative analysis. With 997 enrolled participants the Ag-RDT had a sensitivity 71.5% (63.2-78.6) and specificity of 97.5% (96.2-98.5) at cycle threshold value <40. Highest sensitivity of 87.7% (77.2-94.5) was observed in samples with cycle threshold values ≤30. NowCheck COVID-19 Ag-RDT performed well at multiple healthcare facilities in an African field setting. Operational specificity and sensitivity were close to WHO-recommended thresholds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.