Abstract

We have made a brief test on the performance of 1.5 m long counters made of a new acrylic scintillator block (ALTSUTIPE BLUE 155). For 1.2 GeV/ c protons, we observed a rather long light attenuation length (nearly 5 m) and good pulse height resolution (6.4% r.m.s.). With a 2″ photomultiplier at each end of the block, 0.23 ns time-of-flight resolution and 3 cm position resolution along the counter length were obtained. Although the light yield is about 1 2 compared to standard plastic scintillators, the acrylic scintillator is now an economical alternative in various applications for high energy physics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.