Abstract

This article aims to improve the performance of the deadbeat (DB) predictive controller for a three-level neutral point clamped (NPC) inverter. The effect of the number of effective vectors considered for the cost function evaluation on steady-state and dynamic performance is investigated. To do that, three DB predictive controllers with different numbers of effective vectors, namely, 19 vectors-based, six vectors-based, and three vectors-based DB, are compared beside the conventional current-based model predictive control (MPC). The neutral-point (NP) voltage is balanced using the redundant vectors. Simulations and experimental tests are performed to evaluate the performance of the competing MPC algorithms in terms of four main criteria, namely: NP voltage balancing error, total harmonic distortion (THD), the computational effort required, average switching frequency, power loss, and sensitivity to parameters mismatch. Compared to conventional MPC, the experimental results show that the three vectors-based DB predictive controller has the best steady-state and dynamic performance with a reduction of computational burden up to 60% and a reduction of the current THD up to 72%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.