Although the cooling channel is a crucial factor for improving the performance of a hot stamping die, only a limited number of studies have been conducted concerning its design technology for patchwork blanks. In this study, a mixed cooling channel (MCC) is proposed to improve the cooling performance of the hot stamping die for patchwork blanks. The MCC is a combination of the straight cooling channel (SCC) and conformal cooling channel (CCC). The cooling capacity, average temperature, standard deviation, and figure of merit (FOM) of the SCC, CCC, and MCC are estimated by conducting three-dimensional transient thermo-fluid simulations. The optimum mass flow ratio of the MCC is determined to be 10% considering the cooling capacity, average temperature, and standard deviation. The MCC exhibits superior cooling performance to the SCC and CCC for all performance indicators because it effectively cools both the heat accumulated patch and the wide blank. In addition, the daily production of the MCC is 7.6–9.0% greater than that of the SCC, and 5.8–6.8% greater than that of the CCC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.