Abstract

A set of system performance tests has been performed and the thermal-hydraulic behaviors were investigated for the passive safety injection system (PSIS) of the SMART design. Major thermal-hydraulic characteristics of core cooling in reactor coolant system and safety injection (SI) in PSIS were investigated using the SMART-ITL. The parametric effects of break size, break location and train number on the PSIS performance were discussed with the relevant SMART-ITL data. Compared with the 2.0 inch SI line break test, the 0.4 inch SI line break test has a milder change of system parameters. The pressure is reduced more quickly, the decrease of water level is slower and the break mass flow rate is higher during the pressurizer safety valve line break than during the SI line break. Major thermal-hydraulic parameters were compared among single, two and full train operation of the PSIS focusing on the effect of train number. It was shown that multiple trains of CMT and SIT were operated independently and the reactor vessel (RV) inventory increased proportionally with the addition of each train. Sufficient SI water was injected into the RV in a passive manner to cool down the reactor core efficiently during the full train test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.