Abstract
A system comprised by a UASB (Upflow Anaerobic Sludge Blanket) reactor followed by two horizontal subsurface-flow constructed wetlands in parallel was evaluated for the treatment of the wastewater generated in the city of Belo Horizonte, Brazil (50 inhabitants each unit). One unit was planted (Typha latifolia) and the other was unplanted. Influent and effluent samples were collected for a period of seven months. The systems were able to produce final effluents with low concentrations of organic matter and suspended solids, but showed not to be efficient in the removal of nutrients. Mean effluent concentrations for the planted and unplanted units were, respectively: BOD: 15 and 19 mg/L; COD: 42 and 64 mg/L; TSS: 3 and 5 mg/L; TN: 27 and 33 mg/L; N-NH(3): 25 and 29 mg/L; P Total: 1.2 and 1.5 mg/L. The planted wetland presented effluent concentrations and removal efficiencies significantly (Wilcoxon matched-pairs test, 5% significance level) better than the unplanted unit for most constituents. The study shows that horizontal subsurface-flow constructed wetlands can be effectively used as a post-treatment option for the effluent from UASB reactors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.