Abstract

A research study evaluating piezoelectric sensors used for collecting Weigh-in-Motion (WIM) data is summarized. The evaluation was sponsored by the Highway Innovative Technology Evaluation Center and consisted of testing the WIM sensors under controlled laboratory and fieldloading conditions in both asphalt concrete (AC) and portland cement concrete (PCC) pavements. The field evaluation of piezoelectric WIM sensors is emphasized. The AC installation was performed at the WesTrack test facility near Reno, Nevada, and the PCC installation was performed at a California Department of Transportation (Caltrans) Heavy Vehicle Simulator test site near Palmdale, California. In addition, a compatibility study of the response of the WIM sensors with different data acquisition systems was conducted at the WesTrack facility. Also, various types of grouts were used in the WIM installations. Results indicated that WIM sensor performance was most dependent on the ability of data acquisition systems to process the raw sensor output accurately.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.