Abstract

This paper presents the performance analysis of 12 kWP rooftop grid-connected photovoltaic (PV) plant installed under net metering Regulation of State Electricity Regulatory Commission in Delhi, India. The analysis is based on the evaluation of various performance parameters such as monthly average reference, array and final yield of PV plant. The highest values of monthly average reference, array and final yield of 4.67, 4.15, and 4.06 h/d, respectively, were recorded for the duration of the analysis. The total annual energy generation for the place is 1147 kWh/kWp. This computes to 13.1% annual average utilisation capacity of the plant. Additionally, the performance ratio of Delhi is observed to be the highest (between 85 and 93%) among other existing PV plant locations.