Abstract
In the present work, a rectangular aluminium absorber duct with perforations on the upper surface is placed inside the glazed solar air heater duct. Numerical analysis is carried out to study its influence on thermo-hydraulic performance. The absorber duct insert absorbs the radiation heat by inducing turbulence across the flow path due to the presence of perforations. The upper and lower passages are varied in terms of height ratio so as to create a pressure differential between them which generates a crossflow phenomenon. The perforation hole diameter and number of rows of holes are varied, and the flow physics is analysed. Results indicated that perforated configuration showed significantly higher thermo hydraulic efficiency than the plain configuration. A duct height ratio of 0.667, two row configuration with a hole diameter of 5 mm showed maximum performance with the values of thermal and thermo-hydraulic efficiency being 83.01% and 87.06% respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.