Abstract

This paper examines the results of experiments conducted on a glazed solar air heater duct which is modified with an additional rectangular duct insert having perforation on its top surface. This modified rectangular duct of varying height is designed to split the incoming air into the absorber. This is presumed to create a pressure difference above and below the perforated surface that will enhance the convective heat transfer due to the cross-flow effect. It is observed from the experiments that the drop in pressure along the absorber passage decreases with an increase in the height, increase in hole diameter, and the number of rows of the hole. It is established from the experiments that thermal efficiency is found to be maximum for the height ratio (h/H) of 0.66 when compared to height ratios of 0.50 and 0.83, perforated duct inserts. Further, by varying the hole diameter ratio and the number of rows, it is noted that two rows of holes with hole diameter ratio of 0.096 configuration gives the maximum thermal efficiency of 84.8% and thermo-hydraulic efficiency of 81.06%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.