Abstract
Comparisons of system performance for the flat plate liquid-heating system in CSU Solar House I, the evacuated-tube collector system in Solar House I, and the flat plate air-heating system in CSU Solar House II are described for selected months of the 1976 and 1977 heating seasons. Only space and domestic water heating data are compared. The flat plate air- and liquid-heating collectors operating with complete heating systems have nearly equal efficiencies when based upon solar flux while the collector fluids are flowing, but approximately 40% more energy is collected during a heating season with the air-heating system because the air system operates over a longer period of the day. On the basis of short-term data, the evacuated tube collector array on Solar House I is about 27% more efficient than the flat plate air-heating collector array on Solar House II based on gross roof area occupied by the collectors and manifolds.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have