Abstract

<span>This paper analyzes the performance of a pico hydropower plant consisting of an axial hydro turbine integrated with a permanent magnet generator (PMG) and connected to a power converter. The proposed system is aimed to obtain a wide system operation range to gain more power captured while maintaining time-harmonic distortion in voltage (THDv) that meets the standard. The PMG specification is 1 kW, 1 phase, 235 V, 50 Hz, 83 rpm. The design and simulation of PMG were carried out by analytical and numerical calculations using FEMM 4.2. The power converter was simulated using PSIM and functions to reduce the THDv and pass the generator voltage between 50–500 V. The results show the THDv of the generating system at the upper and lower limits of the passed voltage having a THDv below 5%. Meanwhile, the PMG performance characteristics at various currents and rotations produce efficiency of 87.20% at nominal current. From these results, it can be concluded that the pico hydropower plant works well as desired.</span>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.