Abstract

A new configuration of Photovoltaic/Thermal Collector (PV/T) system has been designed and proposed. The (PV/T) consists of certain layers which are the glass, air gap, PV panel, absorber plate and insulating material layer. In this paper, a glazed (PV/T) solar collector using the spiral flow design absorber has been studied under different Malaysian meteorological conditions. The Performance of outlet water temperature, thermal, electrical and combined (PV/T) efficiencies under two different Malaysian climatic conditions (sunny and cloudy) days have been evaluated. Based on the simulation results, the maximum hourly thermal efficiency of sunny day is 61.3%, while the maximum hourly thermal efficiency of cloudy day is 59.6%. The electrical efficiencies for typical sunny and cloudy days are 12.89%, 13.03%, respectively. The maximum hourly combined (PV/T) efficiency for typical sunny and cloudy days are 74.1% and 72.63%, respectively. As seen from the results, the proposed (PV/T) system design is applicable to be used under different Malaysian climate conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.