Abstract

Printed circuit heat exchanger could be used as pre-cooler in the supercritical carbon dioxide (S-CO2) Brayton power cycle. Due to the drastic variations of S-CO2 properties in pre-cooler, segmental design method is used to investigate the thermal-hydraulic performance of PCHE. When the heat duty is given, the local heat transfer entropy generation number has extreme value, which appears near the intersection point of the heat capacity flow rates of both sides. In addition, the local and total entropy generation mainly depend on the local and total heat transfer entropy generation, and the flow imbalance increases entropy generation, especially under conditions of the higher local heat capacity flow rate of water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.