Abstract
During the installation process, copper pipes for air conditioning will experience a very large deformation due to straightening and bending following the installation path. Hardening strains occur that result in changes in mechanical properties in this case decreases ductility making it difficult to do the connecting process with flaring.
 Studies need to be carried out to restore the mechanical properties of copper pipes that have been used, including the heat treatment process on copper pipes, so that used copper pipes have a better benefit value than having to be recycled. The temperature of the heat treatment is varied from 400oC, 500 oC and 600 oC.
 Tensile test results show that at annealed temperature of 400 oC has the highest tensile strength of 125.81 N / mm2 and proportional limit stress of 40.52 N / mm2. Whereas in the microhardness test, the highest hardness occurs also at annealed temperature of 400 oC which is equal to 50.8 HV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.