Abstract
The existence of composite resin as dental restorative materials in the mouth will always be exposed to temperature changes from food or drink. The purpose of this study was to evaluate the effect of temperature on water absorption and solubility of the composite resin. Thirty samples made from nanofiller composite resin with a diameter of 15 mm and a thickness of 1 mm. The samples were divided into three test groups (n=10) that is immersed at 50 (I), 37 (II) and 5 °C (III). The testing procedure of water sorption and solubility of the composite resin made according to the ISO 4049: 2000 specifications. Data will be analyzed by one-way ANOVA and Least Significance Data test (p=0,05). The results showed there is significant differences of the water sorption (p=0,045) and solubility (p=0,018). The highest water sorption is group I (0,0057±0,007µg/mm3) than group II (0,0028±0,0013 µg/mm) and group III (0,0005±0,0006 µg/mm). While the heighest solubility values are in group I (0,003 ± 0,0027 µg/ mm), than group II (0,002 ± 0,0013 µg/mm) and group III (0,001 ± 0,00 µg/mm). It can be concluded that temperature could increase water sorption and solubility of composite resin.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.