Abstract

To describe the feasibility of treating a complex and diverse group of patients using pencil beam scanning (PBS) proton stereotactic body radiation therapy (SBRT: 5 or fewer fractions, with a fraction size of at least 5 Gy). Our center treats on average 105-120 PBS proton treatments daily, of which 9.5% of treatment courses are proton SBRT. Statistics of disease sites, treatment planning parameters (target volume, prescriptions, number of fields, SFO vs. MFO), and treatment efficiencies (scheduled time slots, actual treatment time) are presented for 305 consecutive SBRT patients receiving 1507 fractions in the past three years. Thermoplastic masks or Vacuum-lock bags are used to immobilize SBRT patients and index the patients' treatment position. Imaging guidance of orthogonal kV images and volumetric cone-beam CT is routinely used for patient setup. SBRT patients are grouped based on the target locations: pelvis (31%), liver (17%), thoracic (13%), spine (8%), abdominal (8%), brain (7%), non-spine bone (7%), ocular (6%), and head and neck (2%). Only 112 patients (37%) were receiving their 1st RT course, whereas 113 (37%) had one prior in-field RT course, and 80 (26%) had multiple prior in-field RT courses. The median [IQR] target volume was 65.4 [29.3, 168] cc (range: 0.3-2475 cc). 72% of cases were planned with SFO and 28% with MFO. On average, 3.76 fields (range: 2 to 12) were planned for each treatment. 44% of the treatments were planned with three or fewer fields, and 10% received more than five fields, most of which involved repainting for moving targets. Over 97% of treatments were delivered in 5 fractions, with ∼3% delivered in 3 fractions. The median [IQR] prescription per treatment was 8 [7, 10] Gy (range: 5-18 Gy per treatment). 85% (84%) of the SBRT treatments were scheduled (delivered) in a 45-minute or shorter slot, and 6% (7%) of treatments were scheduled (delivered) in over a one-hour slot, most commonly for multiple isocenter treatments. 93% of treatments were delivered within 15 minutes of the planned treatment time or shorter. Deep-inspiration breath-hold (DIBH) was applied to 45% of liver SBRT cases, with the remaining 55% planned on 4D CT with (14%) or without (86%) abdominal compression. DIBH was applied in 13% of lung SBRT cases. The application of other motion mitigation approaches, such as volumetric repainting, was determined by the target motion amplitude and whether the patient could tolerate DIBH. In the most diverse and largest proton SBRT experience delivered in the world over the past 3 years, over 300 patients were treated, demonstrating the feasibility and efficiency of delivering proton SBRT in a very busy center. The planning and treatment parameter statistics reported serve as a helpful reference for the proton community.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call