Abstract

Liposomes are increasingly being studied and implemented as drug delivery systems in the form of eye drops. An important stage in the production of a liposomal preparation in the form of eye drops is the stage of sterilization filtration before filling the medicinal product into a container for final dosage. It is assumed that liposome components interact with the membrane and clog it due to their unique physicochemical properties. Therefore, a deeper understanding of the sterilization filtration of liposomes is needed to make appropriate decisions regarding the choice of filters for sterilization.Resistance and permeability values calculated from the Darcy equation are well suited for comparing different filter membranes or process parameters. Aim. To substantiate the choice of optimal brands of filter membranes and parameters of the liposomal emulsion filtration process for the production of eye drops based on a peptide complex. Materials and methods. The study object was a liposomal emulsion for the production of eye drops based on a peptide complex. A prepared liposomal emulsion of eye drops based on a peptide complex and membrane filters of various brands were used for filtration. Filtration tests were performed on a Zero-T scaling unit manufactured by Sartorius, Germany. For all measurements, the filtrate weight was controlled using a balance. Filtration experiments were evaluated using Zero-T 2.0 software from Sartorius Stedim Biotech, Germany. At the first stage, the recorded data of the results was saved to a file. Based on the data obtained using the Excel table processor, the filtration flow J°, the initial resistance of the membrane R°zag and the throughput Ṽ were calculated according to the calculated measurement time: the beginning of T10 % and the end of T80 %. Results and discussion. According to the results obtained, the optimal brands of sterilizing membranes were determined; it was shown that by increasing the pressure drop, the volumetric throughput was significantly improved by more than 18 times (from 0.7 to 4.1 bar), and in another experiment – by more than 10 times (from 0.3 to 2.1 bar). In addition, the benefit of using a higher pressure drop to filter liposomes through various sterilizing membranes was shown. Conclusions. The obtained values of the initial resistance of the membrane showed that the geometrical aspects and properties of the material of the Supor® (Pall) and Sartopore 2® (Sartorius) membrane brands have a lower ability to block the membrane during filtration and provide the filtration resource due to greater throughput. It has been also shown that the use of a higher pressure drop increases the productivity of the process.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call