Abstract

This paper presents the design, construction and testing of a cylindrical pulsed dielectric barrier discharge (PDBD) reactor aimed to microbiological elimination of Escherichia coli ATCC 8739 bacteria. In the reactor, water flowed continuously and to countercurrent an oxygen gas was injected. The water pumping was carried out with a peristaltic pump type, stainless steel and aluminum constructed, and water was recirculated through norprene tubing. The considered parameters in order to promote energetic efficiency were: the residence time of the water contaminated with bacteria, flow rate of the liquid, shape and material used to build electrodes and dielectric, pressure, and gas injection flow rate. The pulsed power supply parameters are featured by 25-30 kV high voltage, 500 Hz frequency and 30 μs width. The outcome elimination of E. coli bacteria at 103, 104 and 106 CFU/mL concentrations reached an efficiency over 0.5 log-order in absence of oxygen; while >2 log- orders when oxygen gas was injected during the process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.